  "legislation_title": "Council Decision of 13 November 2012 on the signing and conclusion of the Agreement between the Government of the United States of America and the European Union on the coordination of energy-efficiency labelling programmes for office equipment (Text with EEA relevance) (2013/107/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2013-107",
  "path": "schedule/ANNEX C/division/III./division/D./division/3./division/(c)",
  "kind": "division",
  "number": "(c)",
  "heading": "Power Measurement Method",
  "text": "All power measurements are to be made in accordance with IEC 62301 with the following exceptions:\nTo determine the voltage/frequency combinations to be used during testing, see the Test Conditions and Equipment for ENERGY STAR Imaging Equipment Products in section D.4.\nThe harmonics requirement used during testing is more stringent than that required by IEC 62301.\nThe accuracy requirement for this OM test procedure is 2 % for all measurements except for Ready power. The accuracy requirement for measuring Ready power is 5 %, as provided in section D.4. The 2 % figure is consistent with IEC 62301, although the IEC standard expresses it as a confidence level.\nFor products designed to operate using batteries when not connected to the mains, the battery is to be left in place for the test; however, the measurement should not reflect active battery charging beyond maintenance charging (i.e. the battery should be fully charged before beginning the test).\nProducts with external power supplies are to be tested with the product connected to the external power supply.\nProducts powered by a standard low voltage dc supply (e.g. USB, USB PlusPower, IEEE 1394, and Power Over Ethernet) must utilise a suitable AC-powered source for the DC power. This AC-powered source's energy consumption is to be measured and reported for the imaging equipment product under test. For imaging equipment powered by USB, a powered hub serving only the imaging equipment being tested is to be used. For imaging equipment powered by Power Over Ethernet or USB PlusPower, it is acceptable to measure the power distribution device with and without the imaging product connected, and use this difference as the imaging product's consumption. The manufacturer should confirm that this reasonably reflects the unit's DC consumption plus some allowance for power supply and distribution inefficiency.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2013/107/schedule/ANNEX C/division/III./division/D./division/3./division/(c)",
    "retrieved_at": "2026-11-01T15:15:09.798475+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}